Problem:
File server (PDC) + Exchange server crashed
with a blue screen.
Recovery attempt, diagnose:
Local administrator did read back from band
incorrectly. System could not start. I did read back system partition from
backup band once more; system still could not start on Primary Domain
Controller "fileserver-fs"
Status 1999 06 28: Administrator Password
locally to all servers and workstations is missing. No ERD disks are available
for any PC. No original bootable CD-ROM with NT server or Exchange server
software is available, no license to NT server or Exchange server. No backup on
Exchange server. PDC and Exchange servers are not recoverable. Network is down.
Decision: (agreed
with new VD Magnus Lund & Account manager Andrew V, consulted with Klas
Kempe)
Rebuild AIC Network according to the following
plan:
Solution
- New PC Dell Dimension Pentium II -350 MHz is
to be set up with 128 SDRAM, 2 X 9 GB (Quantum Atlas III, Quantum Atlas IV SCSI
disks, Adaptec 2940 U/W-pro SCSI card. Configured as NT server stand-alone with
Exchange server 5,5 + service pack 2. Hardware is to be purchased. Attention!
Available software - BackOffice option for only 10 client licenses.
- In the same time old Exchange PC is to be
rebuild with 2 X 8 GB IDE disks. Configured as NT server, PDC, file server.
Following services is to be configured: DHCP, WINS, DNS. Catalogue structure,
shares, Login bat, Sam database is to be rebuilt.
- One SCSI disk with Economy data and Users
catalogs is to be moved and configured to newly installed Mail server.
Old PDC with 2 X 1 GB disks is to be
reconfigured to BDC and Print server.
8 workstation is to be reinstalled with NT 4 +
service pack 4, Office professional with Outlook client, Explorer 5, Total
Defence Antivirus program, mappings, is to be installed and configured.
4 Client PC with Windows 95 is to be
reconfigured with new domain and Exchange server.
Coala PC (Database) is to be reconfigured with
a new domain.
WWW server with all programs is to be
reinstalled and reconfigured as a stand-alone and is to be part of a new domain.
4 PC is to be physically moved to a new
location (part of a personal reshuffle designed by new VD)
Cables topology is to be redesigned.
3COM 10 ports HUB is to be borrowed from
Datavis.
Estimated time: 40 hours
Actual time: (Alexander Monday - Friday 50
hours, Saturday - 13 hours, Sunday - 4 hours) = 67 hours, Klas Kempe - 6 hours,
Johan Wiman (Klas) -14 hours
Totally: 87 hours
Status 99 07 05, 9.30: OK,
The network is running, however only 10 concurrent
Outlook connections is possible for now. Sharp Licensed CD-ROM is needed to
Exchange site to function properly.